Clean Room Floors

Clean rooms are rooms with controlled air purity parameters, in particular for contaminants such as dust, dirt, bacteria, chemical vapour, etc. For this purpose, TIM-EX company has developed the first Polish flooring system that meets the ISO 14644-1 standard requirements in the ISO 4 class.

Suggested uses:

labs

factories

hospitals

Possible floor finishing:

factory application with electrically conductive covering*

* Our proposal is PVC Forbo Colorex EC.

Technical card

Technical data

Panel

Dimensions:

600 x 600 mm

Panel thickness:

46 mm

Construction material:

steel, powder coated

Perforation:

min. 42%

System weight:

55 kg/m2

Panel weight:

15 kg / piece

System height:

from 150 to 2,000 mm

Load values

Point load in accordance with PN – EN 12825:

5,000 N

Vertical movement class:

5A

Load-bearing capacity class in accordance with EN 12825:

class 1

Destructive force:

≥ 10,000 N

Safety factor:

≥ 2.0